中文

  • Home
  • About UsOverview | Mission & Vision | Our Customers | Business Partners | Approvals & Certifications | Milestones
  • ProductsProduct Categories | Business Solutions | Addison & Your Business | Ordering & Testing Information | Warranty
  • Download Product Catalogue | Online Document Viewing
  • Technical Lib Cable Related Standards | Cable Testing & Fire Resistant Cable | Cabling System Library | Material Properties | Cable Glossary
  • Contact
  • Enquiry
  • Sitemap
  • Links Testing Authorities | Testing Equipment Manufacturers | Cable Magazines | Cable Organizations | Addison Corporater Website
  • Airport Cables
  • Alarm & Audio Cables
  • Aluminium Conductor Cables
  • Automotive Cables
  • Belden Equivalent Cables
  • Bus Cables
  • BS standard Cables
    • BS 5308
    • BS 5467
    • BS 6346
    • BS 6724
    • BS 7211
    • BS 8573
  • Coaxial Cables
  • Cable Glands
  • Cables for Oil Industry
  • Control Cables
  • Composite Cables
  • Data Cable
  • Elevator Cables
  • Fiber Optic Cables
  • Fire Resisting Cables
    • Fire Resisting Cable
    • LSZH Flame Retardant Cable
    • PVC Flame Retardant Cable
  • Flexible Cables
  • Heat Detection Cables
  • High Temperature Cables
  • Highway Cables
  • IEC 60502-1
  • Industrial Cables
    • American (UL) Standard
    • Australian Standard (LV)
    • Australian Standard (MV)
    • British Standard
    • French Standard
    • German Standard
    • Harmonized Code
    • Itanlian Standard
    • JIS Standard
    • Spanish Standard
    • Portuguese Standard
  • Instrumentation Cables
  • Lan Cables
  • Offshore Cables
    • NEK606
    • BS6883 & BS7917
    • UKOOA
    • IEC60092
    • JIS
    • Marine & Gas Cables
  • Power Cables
    • Low Voltage Cables
    • Medium Voltage Cables
    • High Voltage Cables
  • Military Cables
  • Mining Cables
  • Motor Connecting Cables
  • Photovoltaic Cables
  • Railway Cables
  • Rolling Stock Cables
  • Robotics
  • Rubber & Crane Cables
  • Security Cables
  • Special Cables
  • Spiral Cables
  • Telephone Cables
  • Thermocouple Cables
  • Windmill Cables
  Special Cables

Trailing cables

Cables for renewable energy
Single Coductor
Airport 400Hz
Truck cables
more

Double insulated, UV-resistant, halogen-free Cable

Application:

The power of the wind, sun and water are alternative power sources which are always available and inexhaustible. These cables are intended for photo-voltaic systems. Photo-voltaic systems convert the energy ofthe sun directly into electric energy. The cable is UV-radiation and temperature resistant and can be used to connect individual solar cells. Because of their excellent weather resistance these cables can also be installed outdoors, but not buried underground or laid in water.

Temperature range:

  • Table1/Table4: flexing -40°C to +80°C,fixed installation -50°C to +90°C
  • Table1/Table3: flexing -30°C to +115°C,fixed installation -40°C to +115°C

Nominal voltage:

  • Table1/Table4: 600/1000 V
  • Table1/Table3: 600/1000 V

A.C. test voltage, 50 Hz:

  • Table1/Table4: 3500 V
  • Table1/Table3: 3500 V

Minimum bending radius:

  • Table1/Table4: for flexible installation,approx. 8x cable Ø
  • Table1/Table3: for flexible installation,approx. 8x cable Ø

Construction:

Table1

  • Bare copper, fine wire conductor to DIN VDE 0295 cl. 5 and IEC 60228 cl. 5
  • 1st insulation TPE
  • 2nd insulation PUR, halogen-free and flame retardant acc. to test method B acc. to VDE 0472 part 804 and IEC 60332-1

Table2

  • Bare copper, fine wire conductor to DIN VDE 0295 cl. 5 and IEC 60228 cl. 5
  • 1st insulation PUR, halogen-free and flame retardant acc. to test method B acc. to VDE 0472 part 804 and IEC 60332-1

Table3

  • Bare copper, fine wire conductor to DIN VDE 0295 cl. 5 and IEC 60228 cl. 5
  • 1st insulation PUR, halogen-free and flame retardant acc. to test method B acc. to VDE 0472 part 804 and IEC 60332-1
  • Armoring of V4A stainless steel

Table4

  • Bare copper, fine wire conductor to DIN VDE 0295 cl. 5 and IEC 60228 cl. 5
  • 1st insulation TPE, PUR
  • 2nd insulation PUR, halogen-free and flame retardant acc. to test method B acc. to VDE 0472 part 804 and IEC 60332-1

Table1

Conductors x cross-sec. mm² Outer Diameter Copper weight
kg/km
Weight ca. kg/km Conductor/ Jacket Color
1x2.5 5.8 24.0 55.0 red/black
1x2.5 5.8 24.0 55.0 blue/black
1x2.5 5.8 24.0 55.0 black/black
1x4 6.7 38.4 85.0 red/black
1x4 6.7 38.4 85.0 blue/black
1x4 6.7 38.4 85.0 black/black
1x6 7.6 57.6 95.0 red/black
1x6 7.6 57.6 95.0 blue/black
1x6 7.6 57.6 95.0 black/black
1x10 9.6 96.0 110.0 black/black
1x10 9.6 96.0 110.0 blue/black
1x10 9.6 96.0 110.0 red/black
1x16 11.0 153.6 170.0 black/black
1x16 11.0 153.6 170.0 blue/black
1x16 11.0 153.6 170.0 red/black

Table2

Conductors x cross-sec. mm² Outer Diameter Copper weight
kg/km
Weight ca. kg/km Conductor/ Jacket Color
1x2.5 6.6 24.0 46.0 black/black
1x2.5 6.6 24.0 46.0 blue/black
1x2.5 6.6 24.0 46.0 red/black
1x4 7.5 38.4 68.0 black/black
1x4 7.5 38.4 68.0 blue/black
1x4 7.5 38.4 68.0 red/black
1x6 8.3 57.6 95.0 black/black
1x6 8.3 57.6 95.0 blue/black
1x6 8.3 57.6 95.0 red/black
1x10 10.2 96.0 110.0 black/black
1x10 10.2 96.0 110.0 blue/black
1x10 10.2 96.0 110.0 red/black
1x16 11.4 153.6 170.0 black/black
1x16 11.4 153.6 170.0 blue/black
1x16 11.4 153.6 170.0 red/black

Table3

Conductors x cross-sec. mm² Outer Diameter Copper weight
kg/km
Weight ca. kg/km Conductor/ Jacket Color
  1x2.5 7.4 24.0 66.0 black/black
  1x4 8.3 38.4 88.0 black/black
  1x6 9.1 57.6 115.0 black/black
  1x10 11.0 96.0 130.0 black/black
  1x16 12.2 153.6 195.0 black/black

Table4

Conductors x cross-sec. mm² Outer Diameter Copper weight
kg/km
Weight ca. kg/km Conductor/ Jacket Color
1x2.5 5.8 24.0 55.0 red/black
1x2.5 5.8 24.0 55.0 blue/black
1x2.5 5.8 24.0 55.0 black/black
1x4 6.3 38.4 80.0 red/black
1x4 6.3 38.4 80.0 blue/black
1x4 6.3 38.4 80.0 black/black
1x6 7.6 57.6 95.0 red/black
1x6 7.6 57.6 95.0 blue/black
1x6 7.6 57.6 95.0 black/black
1x10 9.6 96.0 110.0 red/black
1x10 9.6 96.0 110.0 blue/black
1x10 9.6 96.0 110.0 black/black
1x16 11.0 153.6 170.0 red/black
1x16 11.0 153.6 170.0 blue/black
1x16 11.0 153.6 170.0 black/black

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 


 

Addison

Marchants Industrial Centre, Mill Lane Laughton, 
Lewes, East Sussex, BN8 6AJ, UK

Tel: 44-207-4195087

Fax: 44-207-8319489

Email: sales@addison-cables.com